Periodic maintenance of power source and wire feeder
|
Only qualified service personnel is allowed to carry out periodic maintenance. |
|
Only an authorized electrician is allowed to carry out electrical work. |
|
Before removing the cover plate, disconnect the power source from the mains and wait for about 2 minutes before discharging the capacitor. |
Check the electric connectors of the unit at least every six months. Clean oxidized parts and tighten loose connectors.
|
Use the correct tension torque when fastening loose parts. |
Clean the outside parts of the unit from dust and dirt, for example, with a soft brush and vacuum cleaner. Also clean the ventilation grill at the back of the unit. Do not use compressed air, there is a risk that the dirt will compact even more tightly into gaps of cooling profiles.
|
Do not use pressure washing devices. |
Update the wire feeder to the latest firmware version and load new welding software.