X5 power sources
| X5 Power Source 400 | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 4 mm² | |
| Rated maximum input power [S1max] | 20 kVA | |
| Mains fuse | 25 A | |
| Idle state power consumption [P1idle] | 30 W | |
| No-load state power consumption (MMA), power save | 30 W | |
| No-load state power consumption (MMA), fans ON | 175 W | |
| No-load voltage [U0] | 52...67 V | |
| Open circuit voltage [Uav] | 52...67 V | |
| Effective supply current [I1eff] | 24...21 A | |
| Maximum supply current [I1max] | 28...24 A | |
| Output at +40 °C, 60% MIG | 400 A | |
| Output at +40 °C, 100% MIG | 350 A | |
| Output range, MIG welding current/voltage | 15 A / 12 V ... 400 A / 42 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 400 A / 42 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 400 A / 42 V | |
| Voltage adjustment range (MIG) | 8...45 V | |
| Power factor at rated maximum current | λ | 0.88 |
| Efficiency at rated maximum current | η | 90 % |
| Minimum short-circuit power of supply network [SSC] | 5.8 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 25 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 400 MV WP | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection voltage | MV low range | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 6 mm² | |
| Rated maximum input power [S1max] | 19 kVA | |
| Mains fuse | 25 A | |
| Mains fuse | @MV low range | 32 A |
| Idle state power consumption [P1idle] | 30 W | |
| No-load voltage [U0] | 52...67 V | |
| No-load voltage [U0] | @MV low range | 51 V |
| Open circuit voltage [Uav] | 52...67 V | |
| Effective supply current [I1eff] | 19...23 A | |
| Effective supply current [I1eff] | @MV low range | 30 A |
| Maximum supply current [I1max] | 24...28 A | |
| Maximum supply current [I1max] | @MV low range | 47 A |
| Output at +40 °C, 60% MIG | 400 A | |
| Output at +40 °C, 100% MIG | 350 A | |
| Output, duty cycle % at rated max current, MIG | @MV low range | 40 % |
| Output at +40 °C, rated max current, MIG | @MV low range | 400 A |
| Output at +40 °C, 100% MIG | @MV low range | 300 A |
| Output range, MIG welding current/voltage | 15 A / 12 V ... 400 A / 42 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 400 A / 42 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 400 A / 42 V | |
| Voltage adjustment range (MIG) | 8...45 V | |
| Power factor at rated maximum current | λ | 0.89 |
| Efficiency at rated maximum current | η | 90 % |
| Minimum short-circuit power of supply network [SSC] | 5.8 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Voltage supply for cooling unit | @MV low range | 220...230 V, 24 V |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 25 kVA | |
| EMC class | A | |
| Degree of protection | IP23 | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 43.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 400 Pulse | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 4 mm² | |
| Rated maximum input power [S1max] | 20 kVA | |
| Mains fuse | 25 A | |
| Idle state power consumption [P1idle] | 31 W | |
| No-load state power consumption (MMA), power save | 32 W | |
| No-load state power consumption (MMA), fans ON | 230 W | |
| No-load voltage [U0] | 76...94 V | |
| Open circuit voltage [Uav] | 76...94 V | |
| Effective supply current [I1eff] | 24...22 A | |
| Maximum supply current [I1max] | 28...26 A | |
| Output at +40 °C, 60% MIG | 400 A | |
| Output at +40 °C, 100% MIG | 350 A | |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 400 A / 50 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 400 A / 50 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 400 A / 50 V | |
| Voltage adjustment range (MIG) | 8...50 V | |
| Power factor at rated maximum current | λ | 0.85 |
| Efficiency at rated maximum current | η | 89 % |
| Minimum short-circuit power of supply network [SSC] | 6.3 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 25 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 400 Pulse+ | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 4 mm² | |
| Rated maximum input power [S1max] | 20 kVA | |
| Mains fuse | 25 A | |
| Idle state power consumption [P1idle] | 33 W | |
| No-load state power consumption (MMA), power save | 34 W | |
| No-load state power consumption (MMA), fans ON | 230 W | |
| No-load voltage [U0] | 76...94 V | |
| Open circuit voltage [Uav] | 76...94 V | |
| Effective supply current [I1eff] | 24...22 A | |
| Maximum supply current [I1max] | 28...26 A | |
| Output at +40 °C, 60% MIG | 400 A | |
| Output at +40 °C, 100% MIG | 350 A | |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 400 A / 50 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 400 A / 50 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 400 A / 50 V | |
| Voltage adjustment range (MIG) | 8...50 V | |
| Power factor at rated maximum current | λ | 0.86 |
| Efficiency at rated maximum current | η | 89 % |
| Minimum short-circuit power of supply network [SSC] | 6.3 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 25 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 400 MV Pulse+ | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection voltage | MV low range | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 6 mm² | |
| Rated maximum input power [S1max] | 19 kVA | |
| Mains fuse | 25 A | |
| Mains fuse | @MV low range | 32 A |
| Idle state power consumption [P1idle] | 33 W | |
| No-load state power consumption (MMA), power save | 34 W | |
| No-load state power consumption (MMA), fans ON | 230 W | |
| No-load voltage [U0] | 76...94 V | |
| No-load voltage [U0] | @MV low range | 72 V |
| Open circuit voltage [Uav] | 76...94 V | |
| Effective supply current [I1eff] | 22...19 A | |
| Effective supply current [I1eff] | @MV low range | 30 A |
| Maximum supply current [I1max] | 28...24 A | |
| Maximum supply current [I1max] | @MV low range | 47 A |
| Output at +40 °C, 60% MIG | 400 A | |
| Output at +40 °C, 100% MIG | 350 A | |
| Output, duty cycle % at rated max current, MIG | @MV low range | 40 % |
| Output at +40 °C, rated max current, MIG | @MV low range | 400 A |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 400 A / 45 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 400 A / 45 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 400 A / 45 V | |
| Voltage adjustment range (MIG) | 8...45 V | |
| Power factor at rated maximum current | λ | 0.89 |
| Efficiency at rated maximum current | η | 89 % |
| Minimum short-circuit power of supply network [SSC] | 5.3 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Voltage supply for cooling unit | @MV low range | 220...230 V, 24 V |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 25 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 43.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 500 | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 6 mm² | |
| Rated maximum input power [S1max] | 27 kVA | |
| Mains fuse | 32 A | |
| Idle state power consumption [P1idle] | 30 W | |
| No-load state power consumption (MMA), power save | 30 W | |
| No-load state power consumption (MMA), fans ON | 195 W | |
| No-load voltage [U0] | 59...75 V | |
| Open circuit voltage [Uav] | 59...75 V | |
| Effective supply current [I1eff] | 31...27 A | |
| Maximum supply current [I1max] | 38...33 A | |
| Output at +40 °C, 60% MIG | 500 A | |
| Output at +40 °C, 100% MIG | 430 A | |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 500 A / 47 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 500 A / 47 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 500 A / 47 V | |
| Voltage adjustment range (MIG) | 8...50 V | |
| Power factor at rated maximum current | λ | 0.88 |
| Efficiency at rated maximum current | η | 90 % |
| Minimum short-circuit power of supply network [SSC] | 6.4 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 35 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 500 Pulse | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 6 mm² | |
| Rated maximum input power [S1max] | 27 kVA | |
| Mains fuse | 32 A | |
| Idle state power consumption [P1idle] | 31 W | |
| No-load state power consumption (MMA), power save | 32 W | |
| No-load state power consumption (MMA), fans ON | 240 W | |
| No-load voltage [U0] | 76...94 V | |
| Open circuit voltage [Uav] | 76...94 V | |
| Effective supply current [I1eff] | 30...27 A | |
| Maximum supply current [I1max] | 39...34 A | |
| Output at +40 °C, 60% MIG | 500 A | |
| Output at +40 °C, 100% MIG | 400 A | |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 500 A / 50 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 500 A / 50 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 500 A / 50 V | |
| Voltage adjustment range (MIG) | 8...50 V | |
| Power factor at rated maximum current | λ | 0.89 |
| Efficiency at rated maximum current | η | 89 % |
| Minimum short-circuit power of supply network [SSC] | 6.7 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 35 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39.5 kg | |
| Standards | IEC 60974-1, -10 | |
| X5 Power Source 500 Pulse+ | ||
|---|---|---|
| Feature | Value | |
| Mains connection voltage | 380...460 V ±10 % | |
| Mains connection phases | 3~50/60 Hz | |
| Mains connection cable type | H07RN-F | |
| Mains connection cable size | 6 mm² | |
| Rated maximum input power [S1max] | 27 kVA | |
| Mains fuse | 32 A | |
| Idle state power consumption [P1idle] | 33 W | |
| No-load state power consumption (MMA), power save | 34 W | |
| No-load state power consumption (MMA), fans ON | 240 W | |
| No-load voltage [U0] | 76...94 V | |
| Open circuit voltage [Uav] | 76...94 V | |
| Effective supply current [I1eff] | 30...27 A | |
| Maximum supply current [I1max] | 39...34 A | |
| Output at +40 °C, 60% MIG | 500 A | |
| Output at +40 °C, 100% MIG | 400 A | |
| Output range, MIG welding current/voltage | 15 A / 10 V ... 500 A / 50 V | |
| Output range, TIG welding current/voltage | 15 A / 1 V ... 500 A / 50 V | |
| Output range, MMA welding current/voltage | 15 A / 10 V ... 500 A / 50 V | |
| Voltage adjustment range (MIG) | 8...50 V | |
| Power factor at rated maximum current | λ | 0.89 |
| Efficiency at rated maximum current | η | 88 % |
| Minimum short-circuit power of supply network [SSC] | 6.7 MVA | |
| Voltage supply for auxiliary devices | 12 V, 48 V | |
| Voltage supply for cooling unit | 24 V, 380...460 V | |
| Wired communication type | CAN bus | |
| Operating temperature range | -20...40 °C | |
| Storage temperature range | -40...60 °C | |
| Recommended minimum generator power [Sgen] | 35 kVA | |
| EMC class | A | |
| Degree of protection | IP23S | |
| External dimensions | L x W x H | 750 x 263 x 456 mm |
| Weight without accessories | 39.5 kg | |
| Standards | IEC 60974-1, -10 | |