Using voltage sensing cable
Available with Pulse+ power sources.
While the continuous use of the separate voltage sensing cable is not necessary with X5 FastMig, the voltage sensing cable is required with the advanced WiseRoot+ and WiseThin+ processes. These processes are based on the accurate measurement of arc voltage.
Before welding with WiseRoot+ or WiseThin+ process, connect the voltage sensing cable to the workpiece. For optimal voltage measurement, connect the earth return cable and the voltage sensing cable close to each other and away from the other welding units' cables.
If the voltage sensing cable is not connected or it is broken, an error message is displayed.