Cooling unit

X5 Cooler 1400
Feature Value
Supply voltage   U1 380...460 V +/- 10 %
Maximum supply current @ 380...460 V I1max 0.7 A
Cooling power @ 1 L/min   1.4 kW
Recommended coolant     MGP 4456 (Kemppi mixture)
Maximum coolant pressure     0.4 MPa
Tank volume     3 l
Operating temperature range With recommended coolant   -10...+40 °C
Storage temperature range     -40...+60 °C
EMC class     A
Degree of protection When mounted   IP23S
External dimensions L x W x H   763 x 263 x 288 mm
Weight Without accessories   15 kg
Standards     IEC 60974-2, -10